CONTACT ANGLE METER:

        

 

Dyne Technology offers the CAM PLUS, contact angle meter for surface energy testing of films or solid substrates. A rugged, simple-to-use, highly repeatable QC and analytical tool for measuring the contact angle on a variety of substrates.

Contact Angle Measurement is the preferred and most accurate method of much vital laboratory measurement and research for determining the interactions at the solid/gas/liquid interface. The Contact Angle Meter is an ideal industrial or academic tool for product development engineers, R & D engineers who need precision and repeatability. Contact Angle Measurement combines high technology test instrumentation and a non-destructive testing method to allow an accurate, objective and repeatable analysis to be made. Using the CAM PLUS contact angle meter you can compare the effects of a range of surface treatments and gather data that correlates to various surface conditions e.g. lubricity, wettability, surface energy etc.

What is Contact Angle?

The contact angle is the angle at which the liquid/solid/air interface meets the solid surface. When a liquid droplet is set onto a smooth homogeneous horizontal surface, it may spread out over substrate and the contact angle will approach zero if complete wetting takes place. Conversely, if wetting is partial, the resulting contact angle reaches equilibrium in the range of the material’s surface energy. The smaller the contact angle the greater the wettability or surface energy of the substrate is said to be. Contact angle is a good measure of surface wettability.

Various methods of measuring surface wettability are available from Dyne Technology: Contact Angle Measurement, Dyne Test Pens, Dyne Test inks/fluids etc.

                                          

Half-Angle Technique-Repeatability in Measurements.
By drawing a line from the liquid/solid/air interface point and the apex of a droplet of distilled water the contact angle can be more accurately and precisely identified. This “half angle” measurement technique eliminates potential sources of human error in finding the tangent line.

Projection Technique - Simplifies Discussion of Results.
By projecting the image of the droplet as it sits on top of the substrate, several engineers, students, researchers or QC personnel can simultaneously see and discuss the results of the work. With the Cam Plus contact angle meter the droplet image is magnified and displayed right-side-up for simpler measurements.

 
 

The “Dyne” CAM PLUS series Contact Angle Meter is available in 3 models:

 

“Dyne” CAM PLUS FILM

For measurement of film materials up to a thickness of 250 microns (meets ASTM D5946 and TAPPI T565 pm-96 standards) , comes equipped with a spot-ionizing static eliminator.

To order/enquire about CAM PLUS FILM Contact Angle Meter, click here:   ENQUIRE / ORDER

 

“Dyne” CAM PLUS MICRO

For measurement of samples up to 50mm x 50mm with a maximum thickness of 25mm

To order/enquire about CAM PLUS MICRO Contact Angle Meter, click here:   ENQUIRE / ORDER

 

“Dyne” CAM PLUS COMBO
Used to measure the contact angles on either film or non-film surfaces, combining the features of both the film and micro models, comes equipped with a spot-ionizing static eliminator.

To order/enquire about CAM PLUS COMBO Contact Angle Meter, click here:   ENQUIRE / ORDER

 

“Dyne” CAM-PLUS FILM

For measurement of film materials up to a thickness of 250 microns

The CAM-PLUS FILM contact angle meter has the following features:

ü       Easy to use “half angle” measurement

ü       The high performance light source is remotely sited to avoid sample heating

ü       Fibre optic feed from light source to projection lens.

ü       Projection screen with a protractor .

ü       Clear and bright drop image is projected on to a large screen for easy interpretation of results

ü       A film specimen holder for constant film tension

ü       Accurate liquid dispensing micrometer syringe gives delicate liquid placement (sessile drop)

ü       Measurement range: 0º - 180º

ü       Film sample size: 25mm wide strips

ü       Film thickness: up to 250 microns

ü       Magnification: 6X

ü       Repeatability: ± 2°

ü       Dosing: 50 – 75 droplets

ü       Static control package (ionizer)

 

Approximate dimensions

Main body            L x W x H    457mm x 200mm x 381mm    Weight    12.7kg

Light source:        L x W x H    200mm x 178mm x 127mm     Weight     5.4kg

Fibre Optic Cable        L                      863mm

 

Meets ASTM D5946 and TAPPI T565 pm-96

Accessories and Spare Parts

Advancing/Receding Angle Kit: Allows measurement of recently advanced and recently receded contact angles. Includes five small 28 gauge needles and advance/recede measuring screen.

To order/enquire about CAM PLUS FILM Contact Angle Meter, click here:   ENQUIRE / ORDER

 

For more information on surface energy measurement please see our FAQ page:

 

“Dyne” CAM-PLUS MICRO

For measurement of samples up to a thickness of 25mm

The CAM-PLUS MICRO contact angle meter has the following features:

ü       Easy to use “half angle” measurement

ü       The high performance light source is remotely sited to avoid sample heating

ü       Fibre optic feed from light source to projection lens.

ü       Projection screen with a protractor.

ü       Clear and bright drop image is projected on to a large screen for easy interpretation of results

ü       A specimen holder for positive sample location

ü       Accurate liquid dispensing micrometer syringe gives delicate liquid placement (sessile drop)

ü       Measurement range: 0º - 180º

ü       Sample size max: 50mm (L) x 50mm (W)

ü       Sample thickness: up to 25mm

ü       Magnification: 12X (Option 6X)

ü       Accuracy: ± 1.5°

ü       Repeatability: ± 2°

ü       Dosing: 50 – 75 droplets

 

Approximate dimensions

Main body        L x W x H    457mm x 200mm x 381mm    Weight     12.7kg

Light source:    L x W x H    200mm x 178mm x 127mm    Weight     5.4kg

Fibre Optic Cable   L                      863mm

 

Options:

Sliding platforms 47mm, 40mm, and 30mm for Plastic Ball Grid Array (PBGA), PCB’s

Static Eliminator Package.

6X Magnification

Accessories and Spare Parts

Advancing/Receding Angle Kit: Allows measurement of recently advanced and recently receded contact angles. Includes five small 28 gauge needles and advance/recede measuring screen.

Static Control Package (Ionizer): Includes static neutralizer with mounting kit for measuring materials with static charges present on the surface which can affect the results

To order/enquire about CAM PLUS MICRO Contact Angle Meter, click here:   ENQUIRE / ORDER

 

For more information on surface energy measurement please see our FAQ page:

 

“Dyne” CAM-PLUS COMBO

The CAM-PLUS COMBO contact angle meter is used to measure the contact angles on either film (meets ASTM D5946 and TAPPI T565 pm-96) or non-film surfaces, combining the features of both the film and micro models and comes equipped with a spot-ionizing static eliminator. The CAM PLUS COMBO has the following features:

ü       Easy to use “half angle” measurement

ü       The high performance light source is remotely sited to avoid sample heating

ü       Fibre optic feed from light source to projection lens.

ü       Projection screen with a protractor .

ü       Clear and bright drop image is projected on to a large screen for easy interpretation of results

ü       Specimen holders for Film and Solid samples.

ü       Accurate liquid dispensing micrometer syringe gives delicate liquid placement (sessile drop)

ü       Measurement range: 0º - 180º

ü       Film sample size: 25mm wide strips

ü       Film thickness: up to 250 microns

ü       Solid sample size max: 50mm (L) x 50mm (W)

ü       Solid sample thickness: up to 25mm

ü       Repeatability: ± 2°

ü       Dosing: 50 – 75 droplets

ü       Static control package (ionizer) 

Approximate dimensions

Main body            L x W x H        457mm x 200mm x 381mm    Weight     12.7kg

Light source:        L x W x H        200mm x 178mm x 127mm    Weight     5.4kg

Fibre Optic Cable        L                              863mm

Options:

Sliding platforms 47mm, 40mm, and 30mm for Plastic Ball Grid Array (PBGA), PCB’s

Accessories and Spare Parts

Advancing/Receding Angle Kit: Allows measurement of recently advanced and recently receded contact angles. Includes five small 28 gauge needles and advance/recede measuring screen.

To order/enquire about CAM PLUS COMBO Contact Angle Meter, click here:   ENQUIRE / ORDER

 

For more information on surface energy measurement please see our FAQ page:

>> Dyne Home Page

Contact Information:

Phone:    +44 (0) 1543 411460
Fax:        +44 (0) 1543 415140
Post:        Dyne Technology Ltd, Unit 1, The Oak Tree, Elmhurst Business Park, Lichfield, Staffordshire, WS13 8EX, United Kingdom.
E-mail     info@dynetechnology.co.uk

[Home] [Up]

Copyright © 2005 - 2008 Dyne Technology Ltd - All rights reserved.   -   Web Site Design by 2 Stars   -   Last modified: 06/30/08