CONTACT ANGLE
METER:

Dyne Technology offers the
CAM
PLUS,
contact angle meter for surface energy testing of films or solid substrates.
A rugged, simple-to-use, highly repeatable QC and analytical tool for measuring
the contact angle on a variety of substrates.
Contact Angle Measurement is the preferred and most accurate method of much
vital laboratory measurement and research for determining the interactions at
the solid/gas/liquid interface. The Contact Angle Meter is an ideal industrial
or academic tool for product development engineers, R & D engineers who need
precision and repeatability. Contact Angle Measurement combines high technology
test instrumentation and a non-destructive testing method to allow an accurate,
objective and repeatable analysis to be made. Using the CAM PLUS contact angle
meter you can compare the effects of a range of surface treatments and gather
data that correlates to various surface conditions e.g. lubricity, wettability,
surface energy etc.
What is Contact Angle?
The contact angle is the angle at which the liquid/solid/air interface meets the
solid surface. When a liquid droplet is set onto a smooth homogeneous horizontal
surface, it may spread out over substrate and the contact angle will approach
zero if complete wetting takes place. Conversely, if wetting is partial, the
resulting contact angle reaches equilibrium in the range of the material’s
surface energy. The smaller the contact angle the greater the wettability or
surface energy of the substrate is said to be. Contact angle is a good measure
of surface wettability.
Various methods of measuring surface wettability are available from Dyne
Technology: Contact Angle Measurement,
Dyne Test Pens,
Dyne Test inks/fluids
etc.

Half-Angle Technique-Repeatability in Measurements.
By drawing a line from the liquid/solid/air interface point and the apex of a
droplet of distilled water the contact angle can be more accurately and
precisely identified. This “half angle” measurement technique eliminates
potential sources of human error in finding the tangent line.
Projection Technique - Simplifies
Discussion of Results.
By projecting the image of the droplet as it sits on top of the
substrate, several engineers, students, researchers or QC personnel can
simultaneously see and discuss the results of the work. With the Cam Plus
contact angle meter the droplet image is magnified and displayed right-side-up
for simpler measurements.
The “Dyne” CAM PLUS series Contact Angle Meter is available in 3 models:
“Dyne” CAM PLUS FILM
For measurement of
film materials up to a thickness of 250 microns (meets ASTM D5946 and TAPPI T565
pm-96 standards) , comes equipped with a spot-ionizing static eliminator.
To order/enquire about
CAM
PLUS FILM Contact Angle Meter, click here: 
“Dyne” CAM PLUS
MICRO
For measurement of samples up to 50mm x 50mm with a maximum
thickness of 25mm
To order/enquire about
CAM
PLUS MICRO Contact Angle Meter, click here: 
“Dyne” CAM
PLUS COMBO
Used to measure the contact angles on either film or non-film
surfaces, combining the features of both the film and micro models, comes
equipped with a spot-ionizing static eliminator.
To order/enquire about
CAM
PLUS COMBO Contact Angle Meter, click here: 
“Dyne”
CAM-PLUS
FILM
For measurement of film materials up to a thickness of 250 microns
The
CAM-PLUS FILM contact angle meter has the following features:
ü
Easy to use “half angle” measurement
ü
The high performance light source is remotely
sited to avoid sample heating
ü
Fibre optic feed from light source to projection
lens.
ü
Projection screen with a protractor .
ü
Clear and bright drop image is projected on to a
large screen for easy interpretation of results
ü
A film specimen holder for constant film tension
ü
Accurate liquid dispensing micrometer syringe
gives delicate liquid placement (sessile drop)
ü
Measurement range: 0º - 180º
ü
Film sample size: 25mm wide strips
ü
Film thickness: up to 250 microns
ü
Magnification: 6X
ü
Repeatability: ± 2°
ü
Dosing: 50 – 75 droplets
ü
Static control package (ionizer)
Approximate dimensions
Main body L x
W x H 457mm x 200mm x 381mm Weight
12.7kg
Light source: L x W x H
200mm x 178mm x 127mm Weight 5.4kg
Fibre Optic Cable L
863mm
Meets
ASTM
D5946 and TAPPI T565 pm-96
Accessories and
Spare Parts
Advancing/Receding Angle Kit:
Allows measurement of recently advanced and recently receded contact angles.
Includes five small 28 gauge needles and advance/recede measuring screen.
To order/enquire about
CAM
PLUS FILM Contact Angle Meter, click here: 
For more information on surface energy measurement please see our
FAQ page:
“Dyne”
CAM-PLUS
MICRO
For measurement of samples up to a thickness of 25mm
The
CAM-PLUS MICRO contact angle meter has the following features:
ü
Easy to use “half angle” measurement
ü
The high performance light source is remotely
sited to avoid sample heating
ü
Fibre optic feed from light source to projection
lens.
ü
Projection screen with a protractor.
ü
Clear and bright drop image is projected on to a
large screen for easy interpretation of results
ü
A specimen holder for positive sample location
ü
Accurate liquid dispensing micrometer syringe
gives delicate liquid placement (sessile drop)
ü
Measurement range: 0º - 180º
ü
Sample size max: 50mm (L) x 50mm (W)
ü
Sample thickness: up to 25mm
ü
Magnification: 12X (Option 6X)
ü
Accuracy: ± 1.5°
ü
Repeatability: ± 2°
ü
Dosing: 50 – 75 droplets
Approximate dimensions
Main body L x W x H
457mm x 200mm x 381mm Weight 12.7kg
Light source: L x W x H 200mm x 178mm x
127mm Weight 5.4kg
Fibre Optic Cable L
863mm
Options:
Sliding platforms 47mm, 40mm, and 30mm for Plastic Ball Grid Array (PBGA), PCB’s
Static Eliminator Package.
6X Magnification
Accessories and
Spare Parts
Advancing/Receding Angle Kit: Allows measurement of recently advanced and recently
receded contact angles. Includes five small 28 gauge needles and advance/recede
measuring screen.
Static Control Package (Ionizer):
Includes static neutralizer with mounting kit for measuring materials with
static charges present on the surface which can affect the results
To order/enquire about
CAM
PLUS MICRO Contact Angle Meter, click here: 
For more information on surface energy measurement please see our
FAQ page:
“Dyne”
CAM-PLUS
COMBO
The
CAM-PLUS COMBO contact angle meter is used to measure the contact angles on
either film (meets
ASTM
D5946 and TAPPI T565 pm-96) or non-film surfaces, combining the features of both
the film and micro models and comes equipped with a spot-ionizing static
eliminator. The CAM PLUS COMBO has the following features:
ü
Easy to use “half angle” measurement
ü
The high performance light source is remotely
sited to avoid sample heating
ü
Fibre optic feed from light source to projection
lens.
ü
Projection screen with a protractor .
ü
Clear and bright drop image is projected on to a
large screen for easy interpretation of results
ü
Specimen holders for Film and Solid samples.
ü
Accurate liquid dispensing micrometer syringe
gives delicate liquid placement (sessile drop)
ü
Measurement range: 0º - 180º
ü
Film sample size: 25mm wide strips
ü
Film thickness: up to 250 microns
ü
Solid sample size max: 50mm (L) x 50mm (W)
ü
Solid sample thickness: up to 25mm
ü
Repeatability: ± 2°
ü
Dosing: 50 – 75 droplets
ü
Static control package (ionizer)
Approximate dimensions
Main body L x
W x H 457mm x 200mm x 381mm
Weight 12.7kg
Light source: L x W x H 200mm x
178mm x 127mm Weight 5.4kg
Fibre Optic Cable L 863mm
Options:
Sliding platforms 47mm, 40mm, and 30mm for Plastic Ball Grid Array (PBGA), PCB’s
Accessories and Spare
Parts
Advancing/Receding Angle Kit:
Allows measurement of recently advanced and recently receded contact angles.
Includes five small 28 gauge needles and advance/recede measuring screen.
To order/enquire about
CAM
PLUS COMBO Contact Angle Meter, click here: 
For more information on surface energy
measurement please see our FAQ page:
>> Dyne Home Page
Contact Information:
- Phone:
+44 (0) 1543 411460
- Fax:
+44 (0) 1543 415140
- Post:
Dyne Technology Ltd, Unit 1, The Oak Tree, Elmhurst Business Park, Lichfield, Staffordshire, WS13
8EX, United Kingdom.
- E-mail
info@dynetechnology.co.uk
|